APC Smart-UPS 3000VA LCD 2U Rackmount with 12' Cord (Black)

BH #APT3000R2X14 • MFR #SMT3000R2X145
Print
APC Smart-UPS 3000VA LCD 2U Rackmount with 12' Cord (Black)
Key Features
  • 2700W/3000VA Output Power Capacity
  • 120V Nominal Input Voltage
  • 8 x Output Connections
  • 3 Hours Typical Recharge Time
The black Smart-UPS 3000VA LCD 2U Rackmount with 12' Cord from APC provides power to your important computer components in the event of an electrical outage. With sine wave output it eliminates humming and heat generated, when powering tube lights and fans. The UPS's Boost and Trim Automatic Voltage Regulation (AVR) feature eliminates voltage fluctuations preventing AV signal degradation. Its LED indicators provide easy to read status of the unit and utility power conditions. With a predictive replace battery date, this UPS provides the month and year when battery replacement is recommended to aide in long term maintenance planning. Its USB connectivity provides management of the UPS via a USB port.
More Details
Temporarily Out of Stock
No Store Display
Free 2-Day Shipping
Ask an Expert
800-606-6969

APC 3000VA Overview

The black Smart-UPS 3000VA LCD 2U Rackmount with 12' Cord from APC provides power to your important computer components in the event of an electrical outage. With sine wave output it eliminates humming and heat generated, when powering tube lights and fans. The UPS's Boost and Trim Automatic Voltage Regulation (AVR) feature eliminates voltage fluctuations preventing AV signal degradation. Its LED indicators provide easy to read status of the unit and utility power conditions. With a predictive replace battery date, this UPS provides the month and year when battery replacement is recommended to aide in long term maintenance planning. Its USB connectivity provides management of the UPS via a USB port.

StruxureWare Central Compatible
Enables centralized management via StruxureWare central
Predictive Failure Notification
Provides early-warning fault analysis to ensure proactive component replacement
Sine Wave Output
Eliminates humming and heat generated when powering tube lights and fans
LED Indicators
Provide easy to read status of the unit and utility power conditions
Boost and Trim Automatic Voltage Regulation (AVR)
Eliminates voltage fluctuations as a source of AV signal degradation and component power supply stress
Green Mode
This operating mode bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection
Energy Meter
Provides actual kilowatt hours of usage for energy conscious users
Predictive Replace Battery Date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning
Intuitive LCD Interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys
Single Switched Outlet Group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding
Pure Sine Wave Output on Battery
Simulates utility power to provide the high degree of compatibility for active PFC (Power Factor Corrected) servers and sensitive electronics
Disconnected Battery Notification
Warns when a battery is not available to provide backup power
Sequenced Network Shutdown and Reboot
Customize network shutdown and reboot sequence of connected servers and UPSs
Outlet Group Control
Turn on/off, reboot, or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups)
Adjustable Voltage Sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications
Adjustable Voltage-Transfer Points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation
Audible Alarms
Provides notification of changing utility power and UPS power conditions
Automatic Restart of Loads after UPS Shutdown
Automatically starts up the connected equipment upon the return of utility power
Automatic Self-Test
Periodic battery self-test ensures early detection of a battery that needs to be replaced
Hot-Swappable Batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Network Manageable
Provides remote power management of the UPS over the network
Battery Failure Notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Safety-Agency Approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment
Serial Connectivity
Provides management of the UPS via a serial port
Temperature-Compensated Battery Charging
Prolongs battery life by regulating the charge voltage according to battery temperature
USB Connectivity
Provides management of the UPS via a USB port
User-Replaceable Batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Intelligent Battery Management
Maximizes battery performance, life, and reliability through intelligent, precision charging
Automatic Restart of Loads after UPS Shutdown
Automatically starts up the connected equipment upon the return of utility power
Power Conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances
SmartSlot
Customize UPS capabilities with management cards
Easy to Install
Innovative design allows fast and easy installation
UPC: 731304294092

APC 3000VA Specs

Key Specs
Total Outlets
6x NEMA 5-15R
2x NEMA 5-20R
Plug Type
NEMA L5-30P
Surge Protection
Yes: 459 Joules
Maximum Wattage
2700 W
Full-Load Runtime
3 Minutes
General
Total Outlets
6x NEMA 5-15R
2x NEMA 5-20R
Plug Type
NEMA L5-30P
SmartSlot Interface
1
Communications I/O
Serial via RJ45
USB via USB-B
Power
Surge Protection
Yes: 459 Joules
Maximum Wattage
2700 W
Nominal Input Voltage
120 VAC
Input Voltage Adjustable Range
75 to 154 VAC
Input Frequency
50/60 Hz ± 3 Hz (Auto Sensing)
Nominal Output Voltage
120 VAC
Load Capacity
3000 VA
Thermal Dissipation
348 BTU/Hour
Maximum Efficiency
97.6%
Waveform
Sine Wave
Battery
Chemistry
Lead-Acid
Full-Load Runtime
3 Minutes
Half-Load Runtime
11 Minute
Recharge Time
3 Hours
Number of Batteries
1
Replacement Battery
RBC43
Physical
Operating Conditions
32 to 104°F / 0 to 40°C up to 95% Humidity
Noise Level
55 dBA
Certifications
REACH, RoHS
Cable Length
12' / 3.6 m
Rackmount Size
2 U (with Included Hardware)
Dimensions (W x H x D)
18.9 x 3.4 x 26.9" / 48 x 8.6 x 68.3 cm
Weight
97.4 lb / 44.3 kg
Packaging Info
Package Weight
120.6 lb
Box Dimensions (LxWxH)
38 x 24 x 9"