APC SMX3000LVNC Smart-UPS X 3000VA Rack/Tower with Network Card (100-127V)

BH #APSU3000 • MFR #SMX3000LVNC
Print
APC SMX3000LVNC Smart-UPS X 3000VA Rack/Tower with Network Card (100-127V)
Key Features
  • Output: 2700W / 3000VA
  • Input: 120V
  • 6 x NEMA 5-15R Outlets
  • 1 x NEMA L5-20R Outlet
Keep your servers, routers, switches, and other business-critical applications running during a power outage with the SMX3000LVNC Smart-UPS X 3000VA Rack/Tower with Network Card from APC. Capable of up to 2700W of power output, the SMX3000LVNC comes equipped with six NEMA 5-15R outlets, one NEMA L5-20R outlet, and three NEMA 5-20R outlets.
More Details
In Stock
No Store Display
$2,978.99
Calculate Shipping
Protect Your Gear
Add a protection plan from $139.99
Ask an Expert
212-444-6615

APC 3000VA Overview

Keep your servers, routers, switches, and other business-critical applications running during a power outage with the SMX3000LVNC Smart-UPS X 3000VA Rack/Tower with Network Card from APC. Capable of up to 2700W of power output, the SMX3000LVNC comes equipped with six NEMA 5-15R outlets, one NEMA L5-20R outlet, and three NEMA 5-20R outlets.

With a three-hour recharge time, the SMX3000LVNC comes with audible alarms to warn you of changing power conditions. The cold start-capable UPS also boasts a pre-installed network card, hot-swappable batteries, and a $150000 lifetime equipment protection policy.

Adjustable Voltage Sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable Voltage-Transfer Points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
APC USB Communications
Enables communications with SMX, SMT, SRT, and SURTD Smart-UPS models using historical APC proprietary USB usages.
Audible Alarms
Provides notification of changing utility power and UPS power conditions.
Auto Recognition of External Batteries
UPS recognizes when external battery packs are attached and automatically adjusts runtime.
Automatic Restart of Loads after UPS Shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic Self-Test
Periodic battery self-test helps to ensure early detection of a battery that needs to be replaced.
Battery Failure Notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance.
Boost and Trim Automatic Voltage Regulation (AVR)
Helps to eliminate voltage fluctuations as a source of AV signal degradation and component power-supply stress.
Cold-Start Capable
Provides temporary battery power when the utility power is out.
Disconnected Battery Notification
Warns when a battery is not available to provide backup power.
Energy Meter
Provides actual kilowatt hours of usage for energy conscious users.
Green Mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.
High-Frequency Design
Reduces or eliminates bulky transformers resulting in lighter units for ease of handling.
High Online Efficiency
Reduces utility costs, generates less heat.
Hot-Swappable Batteries
Helps to ensure clean, uninterrupted power to protected equipment while batteries are being replaced.
Intelligent Battery Management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Intuitive LCD Interface
Designed to provide clear and accurate information in multiple languages with the ability to configure the UPS locally. Equipped with easy-to-use navigation keys.
Load Shedding
Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime.
Multiple Switched Outlet Groups
Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
Network Manageable
Provides proactive notifications of changing power or unit conditions and provides the user the ability to remotely control PMU functions.
Outlet Group Control
Turn on/off, reboot, or shut down select outlet groups to save dispatching technicians to remote locations.
Overload Protection
Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.
Predicative Failure Notification
Provides early-warning fault analysis ensuring proactive component replacement.
Predictive Replace Battery Date
Dynamically provides the month and year when battery replacement is recommended.
Pre-Installed Network Management Card
Provides for remote management and control of the UPS over a network out of the box.
Pure Sine Wave Output on Battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Rack/Tower Convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Safety-Agency Approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Scalable Runtime
Allows additional run time to be quickly added as needed.
Sequenced Network Shutdown and Reboot
Customize network shutdown and reboot sequence of connected servers and UPSs.
Serial Connectivity
Use any Home Automation network to monitor and control the S20 through its RS-232 serial port.
StruxureWare Data Center Expert Compatible
Enables centralized management via StruxureWare Data Center Expert.
Temperature-Compensated Battery Charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
USB Connectivity
Provides management of the UPS via a USB port.
User-Replaceable Batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries, which helps to reduce Mean Time to Repair (MTTR).
Resettable Circuit Breakers
Enables a quick recovery from overload events.
Power Conditioning
Helps to protect connected loads from surges, spikes, lightning, and other power disturbances.
LED Status Indicators
Quickly understand unit and power status with visual indicators.
UPC: 731304292654

APC 3000VA Specs

Key Specs
Total Outlets
6x NEMA 5-15R
1x NEMA L5-30R
3x NEMA 5-20R
Plug Type
NEMA L5-30P
Surge Protection
Yes: 540 Joules
Maximum Wattage
2700 W
Full-Load Runtime
11 Minutes
General
Total Outlets
6x NEMA 5-15R
1x NEMA L5-30R
3x NEMA 5-20R
Protected Outlets
6x NEMA 5-15R (Battery and Surge)
1x NEMA L5-30R (Battery and Surge)
3x NEMA 5-20R (Battery and Surge)
Plug Type
NEMA L5-30P
SmartSlot Interface
1
Communications I/O
Serial via RJ45
USB via USB-B
Emergency Power Off (EPO) Support
Yes
Topology
Line Interactive
Transfer Time
2 to 8 ms
Power
Surge Protection
Yes: 540 Joules
Current
15 A
Maximum Wattage
2700 W
Nominal Input Voltage
120 VAC
Input Voltage Range
70 to 153 VAC
Input Frequency
50/60 Hz ± 3 Hz (Auto Sensing)
Nominal Output Voltage
120 VAC
Output Voltage Range
100 to 127 VAC
Output Frequency
50/60 Hz ± 3 Hz
Voltage Distortion
<5%
Load Capacity
3000 VA
Thermal Dissipation
276 BTU/Hour
Waveform
Sine Wave
Battery
Chemistry
Lead-Acid
Full-Load Runtime
11 Minutes
Half-Load Runtime
27.5 Minutes
Recharge Time
3 Hours
Number of Batteries
1
User Replaceable
Yes
Replacement Battery
SURTA2000RMXL2U
Hot-Swap Support
Yes
Physical
Operating Conditions
32 to 72°F / 0 to 40°C up to 95% Humidity
Noise Level
55 dBA
Certifications
BSMI, CSA, FCC, REACH, RoHS, TUV, UL, VCCI
Cable Length
8' / 2.44 m
Rackmount Size
4 U (with Included Hardware)
Dimensions (W x H x D)
19 x 17 x 7" / 48.26 x 43.18 x 17.78 cm
Weight
85 lb / 38.56 kg
Packaging Info
Package Weight
101 lb
Box Dimensions (LxWxH)
25 x 23 x 13.3"

APC 3000VA Reviews

Excellent

By Donnie
Rated 5 out of 5
Date: 2021-02-03

Nice & easy

Size Does Matter!

By esstek
Rated 5 out of 5
Date: 2018-02-23

When installing short depth racks (<30") in IDF closets or smaller data centers, don't forget that most 2U UPSes of 1500VA or more capacity are often 27" or more, which, with typical output plugs means you're almost out of clearance! These short depth (~ 19") series UPSes are just the thing, as they save about 8" of depth. Just make sure you have enough rack space for their increased height...

See any errors on this page?

Can I connect up to 15 desktop computers to this ...

Can I connect up to 15 desktop computers to this UPS?
Asked by: ekow
No, the APC SMX3000LVNC Smart-UPS X 3000VA Rack/Tower with Network Card (100-127V) has only 10 outlets, 6 x NEMA 5-15R, 1 x NEMA L5-30R, and 3 x NEMA 5-20R.
Answered by: Paige K
Date published: 2023-04-01

question

normal US 110 AC to NEMA 5 adapter?????????????
Asked by: Anonymous
This UPS uses 110v AC and a NEMA L5-30P connection.
Answered by: James B.
Date published: 2018-08-28

wHAT IS THE PRIMARY SIDE AMPERAGE. wHAT SIZE ...

wHAT IS THE PRIMARY SIDE AMPERAGE. wHAT SIZE BREAKER AND WIRE DO YOU RECOMMEND TO POWER THE SMART-UPS X 3000VA UNIT?
Asked by: Jim
The APC Smart-UPS X 3000VA Rack/Tower LCD 100-127V with Network Card BH #APSMX3RMLV2U requires a 120V 30 amp outlet (30amp breaker).
Answered by: Miguel M
Date published: 2022-01-27

How long is the power cord?

How long is the power cord?
Asked by: Robert
Thank you for your interest in our products. The previous poster is correct that the power cable is 8 feet long.
Answered by: APCProductSupport
Date published: 2024-04-04

For Network Card (200-240V) BH #AP3000RMHUNC • ...

For Network Card (200-240V) BH #AP3000RMHUNC • MFR #SMX3000RMHV2UNC What type of connector is on AC power cord to feed the ups?
Asked by: Robert
Thank you for taking time to provide feedback about our SMX3000RMHV2UNC unit. It has a C20 input and has 3 cables that can serve as a plug a BS1363A British - IEC C19 , a IEC 320 C19 - C20 and a Schuko CEE 7 / EU1-16P to IECC19. If you have other questions We offer email and chat services through our support site. You may also contact us directly at 800-800-4272 option 4 or visit https://www.se.com/us/en/work/support/ and look for the chat icon available from 8AM-8PM EST.
Answered by: APCProductSupport
Date published: 2025-11-24

Hi I am insterested to buying qty 2 or 3 APC ...

Hi I am insterested to buying qty 2 or 3 APC Smart-UPS X 3000VA Rack/Tower with LCD and Network Card (200-240V) BH #AP3000RMHUNC • MFR #SMX3000RMHV2UNC UPS systems that you have in stock and I want to know which warranty are you offering for the battery and the system? Thank you! Patricio Dau, Lyncean Technologies
Asked by: Patricio
This product has a 2 year limited warranty. Please feel free to call or email us for assistance with purchasing this item.
Answered by: Bennie
Date published: 2020-07-02

question

Does this come with rackmount ears?
Asked by: Anonymous
Yes, the APC Smart-UPS X 3000VA Rack/Tower LCD 100-127V with Network Card B&H # APSMX3RMLV2U comes with rackmount ears.In the Box:APC Smart-UPS X 3000VA Rack/Tower LCD 100-127V with Network Card,Rack Mounting Brackets,Rack Mounting Hardware,Rack Mounting Support Rails,Removable Support Feet,Smart UPS Signaling RS-232 Cable,USB Cable,Web/SNMP Management Card,Limited 3-Year Manufacturer Repair or Replace Warranty,Limited 2-Year Manufacturer Warranty for Batteries.
Answered by: Anonymous
Date published: 2018-10-24
  • y_2026, m_7, d_8, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.47
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_7
  • loc_en_US, sid_1242367, prod, sort_[SortEntry(order=HAS_STAFF_ANSWERS, direction=DESCENDING)]
  • clientName_bhphotovideo
Whatever You Need, We've Got It