Holiday Kickoff

CyberPower Smart App Online Series 8U Rack/Tower Sine Wave Double-Conversion UPS with Maintenance Bypass Switch & Step-Down Transformer (8,000VA / 7,200W)

BH #CY8000RT3UPT • MFR #OL8000RT3UPDUTF
Print
CyberPower Smart App Online Series 8U Rack/Tower Sine Wave Double-Conversion UPS with Maintenance Bypass Switch & Step-Down Transformer (8,000VA / 7,200W)
No Longer Available
No Store Display
Ask an Expert
800-606-6969

CyberPower OL8000RT3UPDUTF Overview

The Smart App Online Series Sine Wave Double-Conversion UPS from CyberPower is an 8U rack/tower uninterruptible power supply (UPS) with Maintenance Bypass Switch and Step-Down Transformer. It comprises of a 3U power module, 3U battery module, PDU module, and 2U step-down transformer. This UPS provides an 8,000VA / 7,200W sine wave output to mission-critical applications and equipment requiring seamless power protection.

The Maintenance Bypass Switch allows you to hot-swap the power module for service or replacement without cutting power to the connected equipment. This unit is generator compatible and delivers consistent and clean 120V or 200 to 240V AC power with zero transfer time. Auto-bypass ensures connected equipment continues to operate seamlessly when an overload or internal fault is detected.

The UPS unit features an LCD control panel (extendable with an optional cable), Smart Battery Management (SBM) charging design, Fast Charge Technology, and the energy-saving GreenPower UPS ECO mode. The model can use the BP240V30ART3U Extended Battery Module (available separately) for expanded runtime and faster restoration of full backup power.

Data Line Protection
  • Prevents power surges that travel through telephone and Ethernet lines from causing damage to electronics.
Double-Conversion Topology
  • Provides consistent and clean power supply, regardless of the condition of incoming power.
  • With this technology, the system operates on isolated DC power 100% of the time and has a zero-transfer time because it never needs to switch to battery.
  • This double-conversion UPS system is designed for high-end system components, corporate servers, lab equipment, and other sensitive electronic devices.
Sine Wave Output
  • Provides power protection to ENERGY STAR 6.0 systems with Active PFC power supplies.
Step-Down Transformer
  • Supports 120V and 200-240V output requirements with a single UPS solution.
  • Offers six NEMA 5-20R outlets for connecting multiple 120V devices running at 15A and/or 20A (a CyberPower PDU can be purchased separately, if additional outlets are required).
Maintenance Bypass Switch
  • Allows IT managers to service or replace the UPS without powering down the connected equipment.
  • An interlock bracket enables the UPS to automatically switch to internal bypass mode, making the hot-swap process easier and quicker to complete.
Extendable LCD Panel
  • Displays UPS statuses and customizable operating settings.
  • 43-setting LCD control panel can be removed and mounted up to 10’ away from the UPS away with a separately available cable.
  • Users can check UPS status, manage setup and control, and run battery test options.
  • Status and log menus provide UPS vitals, including input and output voltage levels, battery information, runtime estimates, load information, event and fault logging, and other system information.
  • Configuration menu offers IT managers the ability to customize the UPS operation.
Multiple Language Options
  • LCD Control Panel can be configured in English, Spanish, French, and German for ease of use.
Extended Battery Module (EBM)
  • Extends runtime by adding BP240V30ART3U EBMs (available separately).
  • Up to ten modules can be added to this UPS unit.
Fast Charge Technology
  • Allows UPS batteries to return to 100% capacity more rapidly by utilizing a built-in charger inside each EBM.
  • Restores a complete charge within 5 hours regardless of the number of EBMs.
Smart Battery Management (SBM)
  • Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process.
  • First cycle charges the battery to full capacity, the second cycle enters float mode, and the final cycle turns the charger off and allows the battery to naturally discharge (rest) until it reaches a set point.
  • After a slight discharge, the UPS will restart the process, ensuring that runtimes are maintained.
GreenPower UPS ECO Mode
  • Improves UPS efficiency up to 95%; saves on electrical and cooling costs.
Hot-Swappable Batteries
  • Eliminate downtime related to UPS power maintenance for continuous power availability.
Critical & Non-Critical Loads
  • UPS has two banks of outlets which can be configured so that the non-critical loads shut off after a set timeframe to provide additional runtime for the critical load outlet.
  • Users can prioritize their equipment runtimes to maximize the output of the UPS to meet their power requirements.
Emergency Power Off (EPO)
  • Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.
Backfeed Protection
  • Prevents the risk of electric shock from any electric current feeding back from the UPS through the input terminals when utility power is lost.
  • Isolates the UPS and allows service personnel to safely work on the utility power.
Generator Compatible
  • Provides stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.
Converter Mode
  • Provides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50 or 60 Hz output on the LCD control panel.
USB & Serial Connectivity
  • Enables full integration with built-in power management and auto shutdown features on Windows, Linux, and VMware systems through a HID-compliant USB port and Serial port.
EMI/RFI Filters
  • Prevent electromagnetic and radio frequency interference to ensure clean power for connected equipment.
Audible Alarms
  • Identify when the model is running on battery power, overloaded, or has a low battery.
Resettable Circuit Breaker
  • Interrupts an electric current in a circuit when the current becomes too high.
LED Status Lights
  • Indicate power on, line mode, battery mode, bypass mode, fault, replace battery.
Rack/Tower Versatility
  • Allows for horizontal rack or vertical tower installation.
PowerPanel Business Edition Software (Included)
  • Provides IT professionals with tools for monitoring and managing the UPS and backup power.
  • Offers remote management functionality.
  • Connect your computer to the HID-compliant, USB port, or serial port to use the power management features provided by PowerPanel Business Edition software.
  • Use the separately available RMCARD for remote management.
Connected Equipment Guarantee
  • CyberPower will repair or replace properly connected equipment if it is damaged by a power surge.

CyberPower OL8000RT3UPDUTF Specs

General
UPS Topology
Double-conversion
Input
Voltage
200 to 240 VAC
Input Voltage Range
120 to 139 VAC for 0 to 25% load
140 to 159 VAC for 0 to 50% load
160 to 179 VAC for 0 to 75% load
180 to 280 VAC for 0 to 100% load
Frequency Range
40 to 70 Hz
Power Factor
0.99
Cold Start
Yes
Plug Type
Hardwire
Protection
Backfeed protection
Output
VA
8,000 VA
Watts
7,200 W
On Battery Voltage
200, 208, 220, 230, and 240 VAC (configurable) ± 2%
On Battery Frequency
50/60 Hz ± 0.25 Hz (auto-sensing or configurable)
On Battery Waveform
Sine Wave
Total Outlets
13
Outlet Type
6 x NEMA 5-20R
2 x NEMA L6-20R
4 x NEMA L6-30R
1 x Hardwire Terminal Block
Power Factor
0.9 (rated)
Crest Factor
3:1
Harmonic Distortion
THD < 3% at Linear Load, < 5% at Non-linear Load
Voltage Regulation
ECO Mode: ±10%, ±15% (configurable)
Bypass
Internal bypass (automatic and manual), Maintenance Bypass
Overload Protection
Line Mode:
105 to 125% load for 1 min
126 to 150% load for 10 sec

Battery Mode:
105 to 130% load for 10 sec
131 to 150% load for 2 sec
Short Circuit Protection
UPS output cut off immediately
Input fuse / circuit breaker protection
Transfer Time
0 ms
Battery
Runtime at Half Load
13 minutes
Runtime at Full Load
6 minutes
Battery Type
Sealed lead-acid
Battery Size
12 V / 9 Ah
Battery Quantity
20
Hot-Swappable
Yes
User Replaceable
Yes
Replacement Battery Cartridge
RB1290X20
Replacement Battery Cartridge
1
Typical Recharge Time
5 hours
Extended Battery Packs
BP240V30ART3U module
Mode
Smart Battery Management (SBM) mode
Surge Suppression
2,670 J (IEC 61000-4-5 Level 3)
EMI/RFI Filter
Yes
Management and Communications
LCD Control Panel
Access 43 information status and configuration settings via the Information and Configuration Menus, in addition to an Event Log Menu
Removable LCD Control Panel Option
Yes, requires a separately available DB26 cable
Ports
HID compliant USB port
Serial port
EPO port
Dry contacts
Management Cable
USB cable and Serial cable (both are included)
LED Indicators
White:
Power On

Green:
Line Mode

Yellow:
Battery Mode
Bypass Mode

Red:
Fault
Replace Battery
Audible Alarm
Battery mode
Battery low
Overload
UPS fault
Replace battery
Software
PowerPanel Business Edition (included in a CD)
SNMP/HTTP Remote Monitoring
Yes, with optional RMCARD302, RMCARD303, or RMCARD305
Environmental
Operating Temperature
32 to 104°F (0 to 40°C)
Operating Humidity
0 to 90% (non-condensing)
Operating Elevation
0 to 10,000' (0 to 3,000 m)
Storage Temperature
5 to 113°F (-15 to 45°C)
Storage Relative Humidity
0 to 95% (non-condensing)
Storage Elevation
0 to 50,000' (0 to 15,000 m)
Online Thermal Dissipation
2,460 BTU/hr
Audible Noise
55 dBA at 4.9' (1.5 m) from surface of unit
Certifications
Safety
UL1778
CSA C22.2 NO.107.3-05
FCC DOC Class A
Environmental
RoHS compliant
Energy Saving
ENERGY STAR qualified
ECO Mode Efficiency: >95%
Physical
Rack Size
Overall: 8U
Power & Battery Module: 3U
Transformer Module: 2U
PDU Module: 6U
Form Factor
Rack/Tower
Enclosure Material
Steel
Dimensions
Overall: 17.0 x 13.9 x 32.2" (432 x 353 x 818 mm)
Power & Battery Module: 17.0 x 5.3 x 26.0" (431.8 x 134.6 x 660.4 mm)
PDU Module: 7.8 x 10.4 x 6.3" (198.1 x 264.2 x 160.0 mm)
Transformer Module: 17.0 x 3.5 x 23.6" (432 x 88 x 599 mm)
Weight
Overall: 354 lb (161 kg)
Power Module: 52.8 lb (23.9 kg)
Battery Module: 171.6 lb (77.8 kg)
PDU Module: 9.9 lb (4.5 kg)
Transformer Module: 119.7 lb (54.3 kg)

CyberPower OL8000RT3UPDUTF Reviews