Key Features
  • Isolates Input of Connected Device
  • For 35mm DIN Rail in NEMA Enclosure
  • Two Jensen High-Performance Transformers
  • Eliminates Hum & Buzz from Ground Loops
Ideal for use in performance venues, broadcast houses, and broad-scale AV installations, the Jensen Transformers Iso-Max DIN-2LI is a passive, 2-channel line-input isolator, which prevents and eliminates hum and buzz by isolating the input of the connected device. Designed to work with professional, balanced audio systems, it is also capable of attenuating electromagnetic interference (EMI) and radio frequency interference (RFI) problems. The unit is plug-and-play with no power required, and snaps into place onto a standard 35mm DIN rail, for easy installation in a NEMA electrical enclosure.
More Details
Special Order
Expected availability: 3-4 Months
No Store Display
Free Standard Shipping
Protect Your Gear
Add a protection plan from $26.00
Ask an Expert
866-264-7509

Jensen Transformers DIN-2LI Overview

Ideal for use in performance venues, broadcast houses, and broad-scale AV installations, the Jensen Transformers Iso-Max DIN-2LI is a passive, 2-channel line-input isolator, which prevents and eliminates hum and buzz by isolating the input of the connected device. Designed to work with professional, balanced audio systems, it is also capable of attenuating electromagnetic interference (EMI) and radio frequency interference (RFI) problems. The unit is plug-and-play with no power required, and snaps into place onto a standard 35mm DIN rail, for easy installation in a NEMA electrical enclosure.

The DIN-2LI features a pair of high-performance Jensen transformers with internal Faraday shields, which eliminate ground loops and reduce common-mode noise by as much as 124 dB. The unit delivers a flat frequency-response from 5 Hz to 40 kHz, and can withstand signals in excess of +19 dB at 20 Hz, without discernible distortion.

Connections to and from the Jensen Transformers Iso-Max DIN-2LI are made via removable screw-down wire terminals. The module comes equipped with a gray, molded assembly made from UL94-VO flame-retardant Noryl.

Key Features
  • Passive, 2-channel line-input isolator for professional, balanced audio systems
  • Isolates the input of the connected device
  • Connects between the source and the input destination to eliminate hum and buzz caused by ground loops
  • Reduces electromagnetic interference (EMI) and radio frequency interference (RFI) problems
  • Snaps into place onto a standard 35 mm DIN rail for easy installation in a NEMA electrical enclosure
  • Two Jensen high-performance transformers with internal Faraday shields improve rejection of high-frequency buzz by a factor of 100 to 1000 (40 dB to 60 dB) over traditional transformers 
  • Ruler-flat frequency-response from 5 Hz to 40 kHz 
  • Handles signals in excess of +19 dB at 20 Hz, without discernible distortion 
  • Rejects noise by as much as 124 dB
  • Connections to and from the module are made via removable screw-down wire terminals
  • Made from gray, molded assembly made from UL94-VO flame retardant Noryl
  • Plug-and-play, easy to use, no power required

 

UPC: 676101046621

Jensen Transformers DIN-2LI Specs

Type
Passive line-input isolator
Channels
2
Format
For standard 35 mm DIN rail in National Electrical Manufacturers Association (NEMA) electrical enclosure
Connectors
Removable, screw-down wire terminals
Frequency Response
5 Hz to 40 kHz
Input Impedance
Zi, 1 kHz, +4 dBu, test circuit 1
Minimum: 13.0 kOhms
Typical: 14.1 kOhms
Maximum: 15.0 kOhms
Voltage Gain
1 kHz, +4 dBu, test circuit 1
Minimum: -3.2 dB
Typical: -3.0 dB
Maximum: -2.8 dB
Magnitude Response
20 Hz, +4 dBu, test circuit 1, ref 1 kHz, Rs = 600 Ohms
Minimum: -0.15 dB
Typical: -0.03 dB
Maximum: ±0.0 dB

20 kHz, +4 dBu, test circuit 1, ref 1 kHz, Rs = 600 Ohms
Minimum: -0.35 dB
Typical: -0.20 dB
Maximum: ±0.0 dB
Deviation from Linear Phase
20 Hz to 20 kHz, +4 dBu, test circuit 1, Rs = 600 Ohms
Typical: +1.4 / -0°
Maximum: ±2.0°
Distortion (THD)
1 kHz, +4 dBu, test circuit 1, Rs = 600 Ohms
Typical: <0.001%

20 Hz, +4 dBu, test circuit 1, Rs = 600 Ohms
Typical: 0.04%
Maximum: 0.10%
Maximum Input Level
At 20 Hz, 1% THD, test circuit 1, Rs = 600 Ohms
Minimum: +17 dBu
Typical: +19 dBu
Common Mode Rejection Ratio
60 Hz, test circuit 2
Typical: 124 dB 

3 kHz, test circuit 2
Minimum: 85 dB
Typical: 95 dB

60 Hz, test circuit 3
Typical: 95 dB

3 kHz, test circuit 3
Typical: 85 dB

(600 Ohms balanced source)
Output Impedance
Zo, 1 kHz, test circuit 1, Rs = 600 Ohms
Typical: 3.2 kOhms
Optimal Cable Length
Output
Typical: 3.3' / 1 m
Maximum: 9.8' / 3 m
Turn Ratio
Minimum: 0.999:1
Typical: 1.000:1
Maximum: 1.001:1
Temperature Range
32 to 158°F / 0 to 70°C

(Operation or storage)
Voltage Difference
Minimum: 250 V RMS

(Primary or secondary to shield and case, 60 Hz, 1 minute test duration)
Construction
Gray, molded assembly made from UL94-VO flame-retardant Noryl
Dimensions
3.85 x 2.06 x 2.30" / 97.80 x 52.30 x 58.40 mm
Packaging Info
Package Weight
0.6 lb
Box Dimensions (LxWxH)
4.8 x 3.3 x 3.3"