Designed specifically for their 9.25" EdgeHD optical tube assembly (OTA), the Celestron 0.7x Focal Reducer Lens speeds its focal ratio from an f/10 to a much faster f/7.1 for drastically reduced exposure times with the same results, and wider fields of view. The reducer maintains the EdgeHD optic's flat-field performance through the use of a 4-element lens system using Lanthanum glass, with blackened edges, and anti-reflection fully multi-coated optics. The Reducer is made to attach directly to the back of the EdgeHD OTA which keeps the same back focus for cameras and accessories so there is no need for new gear. A 60mm clear aperture is optimized for larger full-frame sensors to avoid vignetting of the scene.
More DetailsSee any errors on this page?
is there interference of this 9.25 edge hd focal ...
is there interference of this 9.25 edge hd focal reducer with the Celestron motor focuser on same OTA? I have read that there is but do not have the latest call on that. Thanks!
The Focus Motor #94155-A has a notch that was added to allow clearance of the 9.25 EdgeHD Focal Reducer.
Date published: 2021-12-23
I own a nexstar evolution 9.25 sct, will this ...
I own a nexstar evolution 9.25 sct, will this focal reducer fit my Ota?
Regards,
Alberto
Only if thr threads are the same size as on the Celestron Edge HD 925 OTAs
Date published: 2022-04-25
What size are the threads on the front? I'm ...
What size are the threads on the front? I'm guessing 42 or 48? The description says it is "optimized for a 42mm image circle" and then also says "allows for use with larger (full frame) sensors" which is confusing to me as it sounds like its 42 mm but needs to be 48 mm for full frame?
The threads on the Celestron 0.7x Focal Reducer Lens for EdgeHD 925 OTAs
BH #CE07RLEHD925 • MFR #94245 are T2 threads. A T2 or T-mount or T-thread has a width of 42mm with a thread pitch of 0.75mm. An M42 is also 42mm, but with a 1mm thread pitch. DON'T try to intermix the two or you will likely strip the threads on one, the other or both of the things you are trying to force together
Date published: 2022-05-22
Can the reducer be used for visual observation ...
Can the reducer be used for visual observation using 2 inch eyepieces on the 9.5” OTA?
Yes, the Celestron 0.7x Focal Reducer Lens for EdgeHD 925 OTAs can be used for visual observation using 2 inch eyepieces.
Date published: 2025-06-23
What is the weight of the reducer itself? The ...
What is the weight of the reducer itself? The only weight I see is for the package with the reducer.
The weight of the 0.7x Focal Reducer Lens for EdgeHD 9.25 OTA is approximately, 1 lb.