The CP425SLG Standby UPS Backup from CyberPower safeguards electrical devices from surges by offering eight surge-protected outlets, and four of these outlets are powered with an internal battery for when the power goes out. The backup unit is designed for systems using up to 255W of power and comes with a 5' power cord sporting a right-angled plug. To properly shut down your computer when power fails, the unit provides up to 7 minutes of runtime under a half load or 2 minutes of runtime under a full load. Aside from battery power, two battery/surge and two surge outlets feature a widely-spaced design, so you can plug in transformer-sized power adapters without blocking other outlets. Other notable connections include one telephone input and two telephone outputs as well as a USB port for monitoring the UPS, using a computer installed with a free downloadable PowerPanel Personal Edition software program.
Ask Our Experts800-606-6969
Hello, Log InAccount & Orders
Key Features
- Output: 255 Watts / 425 VA
- Input: 96 to 140 VAC
- 4 x Battery-Powered Outlets
- 8 x Surge-Protected NEMA 5-15R Outlets
The CP425SLG Standby UPS Backup from CyberPower safeguards electrical devices from surges by offering eight surge-protected outlets, and four of these outlets are powered with an internal battery for when the power goes out. The backup unit is designed for systems using up to 255W of power and comes with a 5' power cord sporting a right-angled plug. To properly shut down your computer when power fails, the unit provides up to 7 minutes of runtime under a half load or 2 minutes of runtime under a full load. Aside from battery power, two battery/surge and two surge outlets feature a widely-spaced design, so you can plug in transformer-sized power adapters without blocking other outlets. Other notable connections include one telephone input and two telephone outputs as well as a USB port for monitoring the UPS, using a computer installed with a free downloadable PowerPanel Personal Edition software program.
More DetailsNo Longer Available
CP425SLG Standby UPS Backup Overview
Battery Backup
Supplies power long enough for equipment to properly shut down when utility power fails and helps prevent loss of data and minimizes the component stress caused by a hard shutdown
Surge Protection
Diverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage
Data Line Protection
Prevents power surges that travel through telephone lines from causing damage to electronics
Standby Topology
Ensures that when incoming power drops below or surges above safe voltage levels, the UPS switches to DC battery power and then inverts to AC power to run connected equipment
Simulated Sine Wave Output
Uses pulse wave modulation to generate a stepped, approximated sine wave to supply cost-effective battery backup power for equipment that does not require sine wave output
GreenPower UPS High-Efficiency Design
Reduces power consumption by utilizing a compact charger and power inverter to create an efficient backup power system for home and office use
Quiet Design
Minimizes noise during operation for a quieter work environment
Transformer-Spaced Outlets
Accommodate large transformer-based plugs without compromising the access of other outlets
PowerPanel Personal Edition Software
Provides a user-friendly dashboard interface for controlling and monitoring the UPS via a free software download
Connected Equipment Guarantee
CyberPower will repair or replace properly connected equipment if it is damaged by a power surge under the Lifetime $75,000 Connected Equipment Guarantee
CP425SLG Standby UPS Backup Specs
Key Specs
| Total Outlets | |
| Plug Type | |
| Surge Protection | |
| Maximum Wattage | |
| Full-Load Runtime |
| Input |
General
| Output | |
| Total Outlets | |
| Battery | |
| Protected Outlets | |
| Plug Type | |
| Surge Protection and Filtering | |
| Data Line Protection | |
| Management and Communications | |
| Physical | |
| Communications I/O | |
| Agency Certifications | |
| Environmental Requirements | |
| Transfer Time | |
| Dimensions |
Power
| Weight | |
| Surge Protection | |
| Maximum Wattage | |
| Input Voltage Adjustable Range | |
| Input Frequency | |
| Nominal Output Voltage | |
| Output Frequency | |
| Load Capacity | |
| Circuit Breaker Rating | |
| Waveform |
Battery
| Cells | |
| Battery Capacity | |
| Chemistry | |
| Full-Load Runtime | |
| Half-Load Runtime | |
| Recharge Time |
Environmental
| Operating Temperature | |
| Operating Humidity | |
| Certifications |
Physical
| Cable Length | |
| Rackmount Size | |
| Dimensions (W x H x D) | |
| Weight |
Packaging Info
| Package Weight |
CP425SLG Standby UPS Backup Reviews
See any errors on this page?
