CyberPower PR1000RT2UC Smart App Sinewave UPS

BH #CYPR1RT2UC • MFR #PR1000RT2UC
Print
CyberPower PR1000RT2UC Smart App Sinewave UPS
Key Features
  • Output: 1000VA / 1000W
  • Input: 100-125 VAC (Range: 70-155 VAC)
  • 8 x NEMA 5-15R Total Outlets
  • 8 x Battery/Surge & 4 x Critical Outlets
Keep your hardware protected from spikes and outages with the PR1000RT2UC Smart App Sinewave UPS from CyberPower, a rack/tower convertible UPS with line-interactive topology, surge protection, battery backup, and sine wave output to eliminate power gaps that can be detected by sensitive equipment and cause unexpected shutdowns. This uninterruptible power supply (UPS) sports eight NEMA 5-15R outlets, all of which provide surge protection and battery backup, while four also serve as critical load outlets. Providing an output of 1000VA/1000W at 50/60 Hz, the PR1000RT2UC can be used with 120V inputs. Line-interactive topology, automatic voltage regulation, and power-factor correction all ensure your connected equipment is appropriately powered, while a 2430-Joule surge suppression rating and a 12A circuit breaker prevent damage during a spike.
More Details
In Stock
No Store Display
$836.95
Free Expedited Shipping
Protect Your Gear
Add a protection plan from $64.99
Ask an Expert
800-606-6969

CyberPower PR1000RT2UC Overview

Keep your hardware protected from spikes and outages with the PR1000RT2UC Smart App Sinewave UPS from CyberPower, a rack/tower convertible UPS with line-interactive topology, surge protection, battery backup, and sine wave output to eliminate power gaps that can be detected by sensitive equipment and cause unexpected shutdowns. This uninterruptible power supply (UPS) sports eight NEMA 5-15R outlets, all of which provide surge protection and battery backup, while four also serve as critical load outlets. Providing an output of 1000VA/1000W at 50/60 Hz, the PR1000RT2UC can be used with 120V inputs. Line-interactive topology, automatic voltage regulation, and power-factor correction all ensure your connected equipment is appropriately powered, while a 2430-Joule surge suppression rating and a 12A circuit breaker prevent damage during a spike.

This UPS offers runtimes measuring 7 minutes at full load, or 19.5 minutes at half load, while the backup battery has a 3-hour recharge time. The sine wave power output results in low total harmonic distortion and electrical noise for improved line clarity. In addition to an RJ45 port for cloud monitoring, the rear panel also incorporates a USB-B, serial, and EPO ports for communication purposes. The multifunction LCD screen rotates 90° and can be used to monitor battery and power conditions and alerts to potential problems. Use PowerPanel Personal software to control your UPS via a convenient dashboard interface. The PR1000RT2UC utilizes a 10' power cable with a NEMA 5-15P plug for flexible deployment.

Typical Applications
  • Corporate Servers
  • Department Servers
  • Network Devices
  • Storage Devices
  • Telecom Installations
  • VoIP Installations
Battery Backup
Supplies power long enough for equipment to properly shut down when utility power fails. Helps prevent loss of data and minimizes the component stress caused by a hard shutdown.
Surge Protection
Diverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage.
Sine Wave Output
The UPS generates energy that is identical to, or cleaner than the utility company's power grid. Benefits include low total harmonic distortion, minimal electrical noise, and optimal line clarity.
Automatic Voltage Regulation (AVR)
AVR increases or decreases the AC power and maintains a safe voltage level without switching to battery mode and conserving battery life.
Battery Equalization Technology
Battery Equalization is an advanced charging process that maintains the voltages of the batteries at the same level to increase battery life.
Critical Load Outlet
Extend runtimes for critical devices by powering down non-critical equipment to free up battery capacity.
Fast Charge Technology
Allows UPS batteries to return to full capacity more rapidly by using a built-in charger inside of each UPS or EBM.
Rotatable Multifunction LCD Panel
Tilts to provide a better viewing angle when the Smart App Sinewave is mounted low. Rotates 90° when placed in a tower format for horizontal viewing. Provides information on 47 different settings that include UPS status, UPS setup and control management, and testing options.
Toolless Battery Panel Access
Makes battery replacement fast and simple. The faceplate features side latches for easy removal, and captive screws can be loosened by hand to open the battery cover.
Rack/Tower Versatility
Allows for horizontal rack or vertical tower installation.
RMCARD205 Network Management Card
This model accepts the RMCARD205 network management card for remote management and control via a standard web browser or network management system. Built-in cloud monitoring is included.
PowerPanel Business Software
Provides IT professionals with tools for monitoring and managing the UPS and backup power. This software offers remote management functionality. Free software download available. See the Resources tab.
Line-Interactive Topology
Exists when a line-interactive UPS has an autotransformer that regulates low voltages (e.g., brownouts) and over voltages (e.g., spikes) without having to switch to battery.
ENERGY STAR
This model is an ENERGY STAR certified Uninterruptible Power Supply (UPS) system. ENERGY STAR is the trusted, government-backed symbol for energy-efficient products and practices that help save money and protect the environment.
GreenPower UPS Bypass Design
A patented design that allows utility power to bypass the UPS transformer, when AC power is stable, which reduces energy consumption, noise, and heat buildup.
Limited Three-Year Warranty
CyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date.
Connected Equipment Guarantee
CyberPower will repair or replace up to $400,000 of properly connected equipment if it is damaged by a power surge.
UPC: 649532935482

CyberPower PR1000RT2UC Specs

Key Specs
Total Outlets
8x NEMA 5-15R
Plug Type
NEMA 5-15P Offset Right-Angle
Surge Protection
Yes: 2430 Joules
Maximum Wattage
1000 W
Full-Load Runtime
7 Minutes
General
Total Outlets
8x NEMA 5-15R
Protected Outlets
8x NEMA 5-15R (Battery and Surge)
Plug Type
NEMA 5-15P Offset Right-Angle
USB Charging Ports
No
SmartSlot Interface
No
Coax Protection
No
Data Line Protection
No
Communications I/O
USB via USB-B
Serial via DE-9/DB-9
Ethernet (Unspecified) via RJ45
Emergency Power Off (EPO) Support
Yes
Power
Surge Protection
Yes: 2430 Joules
Maximum Wattage
1000 W
Input Voltage Range
75 to 149 VAC
Input Voltage Adjustable Range
70 to 155 VAC
Input Frequency
50/60 Hz ± 10 Hz
Output Voltage Range
100 to 125 VAC
Output Frequency
50/60 Hz ± 1%
Load Capacity
1000 VA
Battery
Battery Capacity
(7 VaH)
Chemistry
Lead-Acid
Full-Load Runtime
7 Minutes
Half-Load Runtime
19.5 Minutes
Recharge Time
3 Hours
User Replaceable
Yes
Replacement Battery
RB1270X4H
Physical
Operating Conditions
32 to 104°F / 0 to 40°C up to 95% Humidity
Noise Level
52.5 dBA
Certifications
CSA, DOE, FCC, RoHS, UL, VCCI
Cable Length
10' / 3 m
Material of Construction
Metal
Rackmount Size
2 U
Dimensions (W x H x D)
17.1 x 3.4 x 16.2" / 434 x 86 x 411 mm
Weight
50.1 lb / 22.72 kg
Packaging Info
Package Weight
58 lb
Box Dimensions (LxWxH)
21.5 x 21 x 10.5"

CyberPower PR1000RT2UC Reviews

See any errors on this page?
Whatever You Need, We've Got It