VERTIV Liebert GXT5 UPS 3000VA Online Rack Tower

BH #LI3KL620RT2U • MFR #GXT5-3KL620RT2UXL
Print
VERTIV Liebert GXT5 UPS 3000VA Online Rack Tower
Key Features
  • Output: 3000VA / 3000W
  • Input: 208 VAC at 60 Hz
  • 1 x NEMA L6-20P Input
  • 2 x NEMA L6-15R
Designed for server rooms, network closets, and other distributed IT applications, this GXT5 UPS 3000VA Online Rack Tower from Liebert offers solid power capacity in a small rack/tower convertible form factor. This UPS has an output of 3000VA / 3000W and an input of 208 VAC at 60 Hz, allowing for the two programmable NEMA L6-15R and NEMA L6-20R outlets to reliably distribute power for optimum battery usage. A NEMA L6-20P is the primary input connection of this UPS.
More Details
Special Order
Expected availability: 7-14 Business Days
No Store Display
Free Standard Shipping
Protect Your Gear
Add a protection plan from $168.99

Business Financing Options

Ask an Expert
800-606-6969

VERTIV Liebert GXT5-3KL620RT2UXL Overview

Designed for server rooms, network closets, and other distributed IT applications, this GXT5 UPS 3000VA Online Rack Tower from Liebert offers solid power capacity in a small rack/tower convertible form factor. This UPS has an output of 3000VA / 3000W and an input of 208 VAC at 60 Hz, allowing for the two programmable NEMA L6-15R and NEMA L6-20R outlets to reliably distribute power for optimum battery usage. A NEMA L6-20P is the primary input connection of this UPS.

Liebert has designed the GTX5 to feature pure sine wave output, a rotatable LCD display panel, a convertible rack/tower design, a hot-swappable internal battery, and output distribution options. The GXT5 sports a recharge time of three hours to 90% and has a runtime of 3 minutes at full-load and 9 minutes at half-load. Remote UPS firmware upgrade and remote management capabilities are possible through the preinstalled RDU101 SNMP/Webcard, so you can view your sensors and tweak settings through a connected network. The addition of intelligent battery health management also optimizes service life and warns you of battery failure, meaning you can remain comfortable that your connected devices are adequately powered.

LCD Display Panel
Provides information about the utility and UPS conditions:

  • Power On/Off
  • Power Mode
  • AVR On/Off
  • Battery Mode
  • Estimated Backup Time
  • Warnings and Fault Codes
  • UPS Operation Parameters
  • Alarms On/Off
  • Overload Information
  • Programmable Outlet Information
USB Connection
Basic monitoring of the GTX5 and unattended controlled shutdown of your computer in case of a power failure can be done using the Liebert Power Assist software via the USB port.
Programmable Outlets
The GTX5 features programmable outlets that can be tweaked to run for a certain amount of time.
Modes of Operation
Normal Mode: When utility power is normal, Normal mode employs the rectifier and inverter to provide voltage and frequency stabilized power to the load. The charger charges the battery in normal mode. On the front panel display, the run-indicator (green) is ON, the alarm indicator is OFF, and the buzzer is silent

Bypass Mode: Bypass mode supplies power to the load from the bypass source (utility power) if an overload or fault occurs during normal operation. On the front panel display, the run indicator (green) is ON, the alarm indicator (yellow) is ON, and the buzzer beeps once every two seconds. The LCD Flow screen displays On Bypass.

Battery Mode: Battery mode supplies battery power to the load if utility power fails or if the utility voltage goes outside of the permissible range. On the front panel display, the run indicator (green) is ON, the alarm indicator (yellow) is ON, and the buzzer beeps once each second. The LCD Flow screen displays On Battery

Eco Mode: The energy-saving ECO mode reduces power consumption by powering the load via bypass if the bypass voltage is normal or by powering the load via the inverter when the bypass voltage is abnormal. You can use ECO mode to power equipment that is not sensitive to power grid quality to via bypass and reduce power consumption.

Maintenance Bypass Mode: Used in the unlikely event that the UPS requires maintenance or repair, maintenance bypass mode powers the connected equipment with utility power while electrically isolating the internal UPS components.

UPC: 767041026610

VERTIV Liebert GXT5-3KL620RT2UXL Reviews

See any errors on this page?
Whatever You Need, We've Got It