UPS Power Backup
Tripp Lite Eaton 9PX 2U Online Double-Conversion UPS (700VA / 630W)
- 700VA Power | 630W
- 8 x NEMA 5-15R Outputs
- 8' NEMA 5-15P Input Connection
- USB & RS-232 Communication Ports
Xtreme Power Conversion P80 1500VA Line Interactive UPS
- 1500VA / 1350W Sine Wave UPS
- Sealed Lead Acid Batteries
- 8 Total Outlets
- 316 Joules Surge Suppression
CyberPower PR1500RT2UC Smart App Sinewave Rack/Tower Convertible UPS
- 1500VA/1500W Load Capacity
- 8 x NEMA 5-15R Outlets
- Line-Interaction Topology & AVR
- $400,000 Connected Equipment Guarantee
VERTIV Liebert GXT5-1000LVRT2UXL UPS
- Output: 1000W / 1000 VA
- Input: 60-150V at 50/60 Hz ±10 Hz
- 6 x NEMA 5-15R Battery & Surge Outlets
- 1 x NEMA 5-15P Input Connection (10')
CyberPower OL1000RTXL2UN Smart App Online UPS
- Output: 1000VA/900W @ 50/60 Hz
- Input: 60-150 VAC @ 40-70 Hz
- 8 x NEMA 5-15R Total Outlets
- 8 x Battery/Surge-Protected Outlets
CyberPower OL2K2RM Essential Online Double Conversion UPS (2200/1600)
- Output: 2200 / 1600 at 50-60 Hz
- Input: 100-125 VAC at 40-70 Hz
- 710 Joules of Surge Suppression
- Recharge Time Under Four Hours (90%)
CyberPower PR3000LCDSL Smart App Sinewave UPS
- Output: 3000 VA / 2700W @ 60 Hz ±1 Hz
- Input: 75-154 VAC @ 47-63 Hz
- 7 x Total Battery/Surge Outlets
- 1 x NEMA L5-30R | 6 x NEMA 5-20R
CyberPower PR1500RTXL2UC Smart App Sinewave Rack/Tower Convertible UPS (TAA Compliant)
- 1500VA/1500W Load Capacity
- 8 x NEMA 5-15R Outlets
- Line-Interaction Topology & AVR
- $400,000 Connected Equipment Guarantee
Tripp Lite SMART2200RMXL2U SmartPro Expandable Rack/Tower UPS System
- 8x Outlets
- 120V Nominal Voltage
- 2200VA/1600W Power Handling
- USB & Serial Communication
CyberPower PR1500RTXL2UCN Smart App Sinewave UPS
- Output: 1500VA / 1500W
- Input: 100-125 VAC (Range: 70-155 VAC)
- 8 × NEMA 5-15R Total Outlets
- 8 x Battery/Surge & 4 x Critical Outlets
CyberPower OL3KRM Essential Online Double Conversion UPS (3000/2400)
- Output: 3000 / 2400 at 50-60 Hz
- Input: 100-125 VAC at 40-70 Hz
- 710 Joules of Surge Suppression
- Recharge Time Under Four Hours (90%)
CyberPower PR2200RTXL2UHVAN Smart App Sinewave UPS
- Output: 2200 VA / 2200W @ 50/60 Hz ±1%
- Input: 131-302 VAC @ 47-63 Hz
- 4 x NEMA 6-20R | 2 x NEMA L6-20R
- 6 x Total Battery/Surge Outlets
APC Smart-UPS Li-Ion Short-Depth 1000VA, 120V Uninterruptible Power Supply with SmartConnect
- 6 x NEMA 5-15R Outlets
- 1 x NEMA 5-15P Power Connection
- USB & Serial RJ45 Communication Ports
- LCD Interface
VERTIV Liebert GXT5-1500LVRT2UXLN UPS with IntelliSlot RDU101 Network Card
- Output: 1350W / 1500 VA
- Input: 60-150V at 50/60 Hz ±10 Hz
- 6 x NEMA 5-15R Battery & Surge Outlets
- 1 x NEMA 5-15P Input Connection (10')
CyberPower PR2000RT2UCN Smart App Sinewave Rack/Tower Convertible UPS
- 2000VA/2000W Load Capacity
- 8 x NEMA 5-20R Outlets
- Line-Interaction Topology & AVR
- $400,000 Connected Equipment Guarantee
CyberPower PR2000RTXL2UCN Smart App Sinewave Rack/Tower Convertible UPS
- 2000VA/2000W Load Capacity
- 8 x NEMA 5-20R Outlets
- Line-Interaction Topology & AVR
- $400,000 Connected Equipment Guarantee
Juice Goose 2000VA / 1800W SCV Series On-Line Double-Conversion Rackmount UPS
- 2000VA / 1800W Power Capacity
- 8 x NEMA 5-20R Outlets
- NEMA 5-20P Input Plug
- On-Line with Pure Sine Wave Power
CyberPower PR3000RT2UCN Smart App Sinewave UPS
- Output: 3000VA / 3000W
- Input: 100-120 VAC (Range: 70-155 VAC)
- 8 × NEMA 5-20R | 1 x NEMA L5-30R
- 9 x Battery/Surge & 4 x Critical Outlets
CyberPower OL2K2RTHD Smart App Double-Conversion Online UPS
- Output: 2200VA / 1800W at 50~60 Hz
- Input: 100-125 VAC at 40~70 Hz
- 6 x NEMA 5-20R | 1 x NEMA L5-20R
- 7 x Individually Controlled Outlets
APC Smart-UPS Battery Backup & Surge Protector with SmartConnect
- Output: 2700W / 2880 VA
- Input: 120 VAC @ 50/60 Hz ±3 Hz
- 8 x NEMA 5-15R Battery Backup Outlets
- 2 x NEMA 5-20R Battery Backup Outlets
VERTIV Liebert GXT5 Lithium UPS Backup (1500VA / 1350W)
- 1500VA / 1350W Output
- 120V Input
- Six NEMA 5-15R Outlets
- Lithium-Ion Replaceable Batteries
CyberPower Smart App Online Series 2U Rack/Tower UPS (3000VA / 2700W)
- Output: 2700 Watts / 3000 VAC
- Input: 120 VAC
- 6 x Battery Powered Outlets
- 6 x NEMA 5-20R and 1 x NEMA L5-30R Outs
APC Smart-UPS X Battery Backup & Surge Protector
- Output: 1980W / 2200 VA
- Input: 100 to 127V @ 50/60 Hz ±3 Hz
- 6 x NEMA 5-15R | 2 x NEMA 5-20R
- 1 x NEMA L5-30P Input Connection (8')
APC Smart-UPS X 2200VA Rack/Tower with LCD (230V)
- Output: 1980W/2200VA
- Input: 230V
- 9x Battery Outlets, 2x Jumpers
- 8x IEC 320 C13, 1x IEC 320 C19
Tripp Lite 9PX1500RT Eaton 9PX 2 RU Online Double-Conversion UPS (1500VA / 1350W)
- 1500 VA / 1350 W Battery Backup
- Input: 120 V @ 50/60 Hz
- Expandable Internal Battery Backup
- Serial Access via RS-232 and USB-B
APC Smart-UPS 3000V RM 2U LCD 208V
- Generator Compatible
- User-Replaceable Batteries
- Automatic Self-Test
- Audible Alarms
APC Smart-UPS X 3000VA Short Depth Tower/Rack Convertible LCD (208V)
- 2700 Watt / 3000 VA Output Power
- 230 V Nominal Output Voltage
- Line Interactive Topology
- Sine Wave Output
Understanding Uninterruptible Power Supplies (UPS) Battery Backup
UPS backups protect computers and prevent loss of data during power outages or brownouts. The principle is simple: Uninterrupted power supplies (UPS) keep the power on for a period, allowing users to safely shut down computer systems. There are various types, each providing a different degree of protection. However, the most crucial decision is selecting a UPS that has enough power to keep your computer system running long enough for it to properly shut down.
Types of UPS Systems
The most common type of UPS is a standby or battery backup system. Under normal conditions, it supplies power from the mains, but automatically switches over to battery backups during power failures. A line interactive UPS is similar, but it also incorporates a special transformer that regulates the output voltage to minimize the effect of power surges and brownouts. While both systems provide a degree of protection against mains disturbances, critical systems often use an online UPS. As the name suggests, this type supplies UPS power all the time. The mains supply charges the UPS battery, which in turn supplies power to the UPS, ensuring there's no possibility of a mains disturbance affecting the power supplied to the load.
Calculating UPS Power Requirements
The first step is to work out how much power you need. Desktop power supplies usually draw the most power, typically between 400 and 650 watts. You may need a technician to open your computer to establish its power supply rating, or alternatively, make a conservative assumption. Other items to consider include monitors, routers, and peripherals. To estimate the required volt-amps, multiply the total wattage by 1.6. A good practice is to choose a UPS that comfortably exceeds this figure. The runtime figures at full and half load give an indication of how long UPS power lasts. Remember that battery capacity, not power rating, is the key factor that determines how long a UPS runs. It's possible to add batteries to some types of UPS units to extend runtime.
Installation of UPS Power Supplies
Smaller UPS systems are freestanding for placement in any convenient location, while larger units are usually rack mounted. Most have several power outlets, and if necessary, you can extend these using power strips. Installation is usually plug and play, and no special tools are necessary. You may need additional AC power and extension cords, especially with a rack-mounted UPS.
Desktop Communication
Most uninterrupted power-supply units have desktop software, allowing you to monitor their status. Additionally, many can automatically shut down your computer in the event of a power failure, which is an important feature for unattended computers. Some types use the computer's serial port, while others connect through a USB port. In some instances, you may need to install a UPS management card in your computer.
Prevent loss of precious data during power failures and brownouts with a UPS backup from B&H Photo and Video.