VERTIV Liebert PSl5-1500MT120 Mini Tower UPS
- Output: 1350W / 1440 VA
- Input: 75-146VAC @ 60Hz (Auto-Sensing)
- 6 x NEMA 5-15R Outlets
- 1 x NEMA 5-15P Input Connection (6')
Minuteman SR1500RMLCD Shallow Rack Series Line-Interactive UPS (1440VA/900W)
- 1440VA / 900W Simulated Sine Wave UPS
- 10 x NEMA 5-15R Outlets
- Surge & Battery Protection
- Surge Protection Up to 1200 Joules
CyberPower OR1500PFCRT2U PFC Sinewave UPS
- Output: 1500 VA / 1050W
- Input: 86-142 VAC
- 8 x NEMA 5-15R Total Outlets
- 8 x Battery/Surge Protected Outlets
CyberPower PR1000LCD Mini-Tower Uninterruptible Power Supply
- Output: 1000 VA / 700 W
- Line-Interactive Topology
- Full AVR Buck / Boost
- GreenPower UPS
CyberPower PR750RT2UC Smart App Sinewave Rack/Tower Convertible UPS
- 750VA/750W Load Capacity
- 8 x NEMA 5-15R Outlets
- Line-Interaction Topology & AVR
- $400,000 Connected Equipment Guarantee
CyberPower M1100XL Medical Grade UPS
- For Hospitals and Healthcare Facilities
- Output: 1100 VA / 800W @ 60 Hz ±1 Hz
- Input: 88-150 VAC @ 57-63 Hz
- 6 x Total NEMA 5-15R-HG Outlets
Juice Goose 750VA / 525W SRA Series On-Line Simulated Sine Wave Rackmount UPS
- 750VA / 525W Power Capacity
- 8 x NEMA 5-15R Outlets
- NEMA 5-15P Input Plug
- On-Line with Simulated Sine Wave Power
APC SMT1000RM1U Smart-UPS Battery Backup & Surge Protector
- Output: 800W / 1000 VA
- Input: 120V at 50/60 Hz ±3 Hz
- 4 x NEMA 5-15R Battery Backup Outlets
- NEMA 5-15P Input Connection (8' Cord)
CyberPower PR1000RT2UC Smart App Sinewave UPS
- Output: 1000VA / 1000W
- Input: 100-125 VAC (Range: 70-155 VAC)
- 8 x NEMA 5-15R Total Outlets
- 8 x Battery/Surge & 4 x Critical Outlets
Tripp Lite SmartPro Line-Interactive Sine Wave UPS
- Battery Backup and Power Protection
- Output: 1440VA / 1440W @ 50/60 Hz
- Input: 80 to 151 VAC
- 8 x NEMA 5-15R Outlets
CyberPower Smart App LCD UPS Series 2U Rack/Tower Line Interactive Sine Wave UPS (2,190 VA / 1,650 W)
CyberPower PR1000RTXL2UC Smart App Sinewave UPS
- Output: 1000VA / 1000W
- Input: 100-125 VAC (Range: 70-155 VAC)
- 8 x NEMA 5-15R Total Outlets
- 8 x Battery/Surge & 4 x Critical Outlets
Tripp Lite SmartPro 1.5kVA Line Interactive Sine Wave UPS
- Optional Battery Expansion
- Network-Grade AC Surge Suppression
- 120V Nominal Output
- SNMPWEBCARD Network Integration
Tripp Lite TAA SmartPro Battery Backup System
- 8 x NEMA 5-15R Outlets
- Rackmountable Design
- Front-Panel LCD Display
- NEMA 5-15P Plug
CyberPower PR1000RT2UCN Smart App Sine Wave UPS
- 1000 VA / 1000W Capacity
- 8 x NEMA 5-15R Outlets
- Surge Protection & Battery Backup
- Up to 7 Minute Runtime at Full Load
CyberPower PR1500RTXL2UC Smart App Sinewave Rack/Tower Convertible UPS
- 1500VA/1500W Load Capacity
- 8 x NEMA 5-15R Outlets
- Line-Interaction Topology & AVR
- $400,000 Connected Equipment Guarantee
APC Smart-UPS SRT Tower Isolation/Step-Down Transformer
- Place Upstream of Your UPS
- Helps Avoid Inrush Current & Saturation
- No Need for an Oversized Transformer
- 8 x NEMA 5-20R Outlets
VERTIV Liebert GXT5-750LVRT2UXLN UPS with IntelliSlot RDU101 Network Card
- Output: 750W / 750 VA
- Input: 60-150V at 50/60 Hz ±10 Hz
- 6 x NEMA 5-15R Battery & Surge Outlets
- 1 x NEMA 5-15P Input Connection (10')
CyberPower PR3000LCDSL Smart App Sinewave UPS
- Output: 3000 VA / 2700W @ 60 Hz ±1 Hz
- Input: 75-154 VAC @ 47-63 Hz
- 7 x Total Battery/Surge Outlets
- 1 x NEMA L5-30R | 6 x NEMA 5-20R
CyberPower PR1500RT2UCN Smart App Sinewave Rack/Tower Convertible UPS
- 1500VA/1500W Load Capacity
- 8 x NEMA 5-15R Outlets
- Line-Interaction Topology & AVR
- $400,000 Connected Equipment Guarantee
Furman F1500-UPS Uninterruptible Power Supply
VERTIV Liebert PSI5-2200RT120 2U Rack/Tower UPS
- Output: 1920W / 1920 VA
- Input: 75-146VAC @ 60Hz
- 1 x L5-20R, 6 x NEMA 5-15/20R Outlets
- 1 x NEMA L5-20P Input Connection (10')
VERTIV Liebert GXT5-1500LVRT2UXL UPS
- Output: 1350W / 1500 VA
- Input: 60-150V at 50/60 Hz ±10 Hz
- 6 x NEMA 5-15R Battery & Surge Outlets
- 1 x NEMA 5-15P Input Connection (10')
CyberPower PR2000RTXL2UC Smart App Sinewave Rack/Tower Convertible UPS
- 2000VA/2000W Load Capacity
- 8 x NEMA 5-20R Outlets
- Line-Interaction Topology & AVR
- $400,000 Connected Equipment Guarantee
CyberPower PR2200RTXL2UHVAN Smart App Sinewave UPS
- Output: 2200 VA / 2200W @ 50/60 Hz ±1%
- Input: 131-302 VAC @ 47-63 Hz
- 4 x NEMA 6-20R | 2 x NEMA L6-20R
- 6 x Total Battery/Surge Outlets
CyberPower OL1K5RTHD Smart App Double-Conversion Online UPS
- Output: 1500VA / 1350W at 50~60 Hz
- Input: 100-125 VAC at 40~70 Hz
- 8 x NEMA 5-15R
- 8 x Individually Controlled Outlets
CyberPower OL1500RTXL2UN Smart App Online UPS
- Output: 1500VA / 1350W @ 50/60 Hz
- Input: 60-150 VAC @ 40-70 Hz
- 8 x NEMA 5-15R Total Outlets
- 8 x Battery/Surge Protected Outlets
VERTIV Liebert PSI5-1500RT120LIN Lithium-Ion 2U Rack/Tower UPS with IntelliSlot RDU120 Network Card
- Output: 1350W / 1500 VA
- Input: 75-146VAC @ 60Hz
- 6 x NEMA 5-15R Outlets
- 1 x NEMA 5-15P Input Connection (10')
Understanding Uninterruptible Power Supplies (UPS) Battery Backup
UPS backups protect computers and prevent loss of data during power outages or brownouts. The principle is simple: Uninterrupted power supplies (UPS) keep the power on for a period, allowing users to safely shut down computer systems. There are various types, each providing a different degree of protection. However, the most crucial decision is selecting a UPS that has enough power to keep your computer system running long enough for it to properly shut down.
Types of UPS Systems
The most common type of UPS is a standby or battery backup system. Under normal conditions, it supplies power from the mains, but automatically switches over to battery backups during power failures. A line interactive UPS is similar, but it also incorporates a special transformer that regulates the output voltage to minimize the effect of power surges and brownouts. While both systems provide a degree of protection against mains disturbances, critical systems often use an online UPS. As the name suggests, this type supplies UPS power all the time. The mains supply charges the UPS battery, which in turn supplies power to the UPS, ensuring there's no possibility of a mains disturbance affecting the power supplied to the load.
Calculating UPS Power Requirements
The first step is to work out how much power you need. Desktop power supplies usually draw the most power, typically between 400 and 650 watts. You may need a technician to open your computer to establish its power supply rating, or alternatively, make a conservative assumption. Other items to consider include monitors, routers, and peripherals. To estimate the required volt-amps, multiply the total wattage by 1.6. A good practice is to choose a UPS that comfortably exceeds this figure. The runtime figures at full and half load give an indication of how long UPS power lasts. Remember that battery capacity, not power rating, is the key factor that determines how long a UPS runs. It's possible to add batteries to some types of UPS units to extend runtime.
Installation of UPS Power Supplies
Smaller UPS systems are freestanding for placement in any convenient location, while larger units are usually rack mounted. Most have several power outlets, and if necessary, you can extend these using power strips. Installation is usually plug and play, and no special tools are necessary. You may need additional AC power and extension cords, especially with a rack-mounted UPS.
Desktop Communication
Most uninterrupted power-supply units have desktop software, allowing you to monitor their status. Additionally, many can automatically shut down your computer in the event of a power failure, which is an important feature for unattended computers. Some types use the computer's serial port, while others connect through a USB port. In some instances, you may need to install a UPS management card in your computer.
Prevent loss of precious data during power failures and brownouts with a UPS backup from B&H Photo and Video.


